Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Journal of the Korean Radiological Society ; : 195-200, 1996.
Article in Korean | WPRIM | ID: wpr-127619

ABSTRACT

PURPOSE: To determine the frequency of complications and diagnostic accuracy of CT-guided percutaneous automated gun biopsy, and to compare the results with those reported for fine needle aspiration. MATERIALS AND METHODS: Using automated biopsy devices, 118 CT-guided percutaneous biopsies of pulmonary lesions were performed. An 18-gauge needle was used. Final diagnosis was made with operation or other methods. We retrospectively analyzed the frequency of complications and diagnostic yields of 118 biopsies. RESULT: Four of 118(3.3%) patients developed pneumothorax and two of these required chest tube insertion. Other complications were resolved spontaneously. 106 biopsies (89.8%) yielded sufficient tissue for pathologic evaluation. For cases of malignant and of benign disease, sensitivity was 91.8% and 87.7% respectively ; the corresponding figures for diagnostic accuracy were 88.5% and 78.9%. CONCLUSION: CT-guided automated gun biopsy of the pulmonary lesions is safe, witha pneumothorax rate comparable to that of fine needle aspiration. In the absence of a trained cytologist at the time of biopsy, the diagnostic accuracy of automated gun biopsy of pulmonary lesions compared favorably with the reported accuracy of fine needle aspiration.


Subject(s)
Biopsy , Biopsy, Fine-Needle , Chest Tubes , Diagnosis , Needles , Pneumothorax , Retrospective Studies
2.
Journal of the Korean Radiological Society ; : 783-785, 1996.
Article in Korean | WPRIM | ID: wpr-28587

ABSTRACT

Acute renal cortical necrosis in which there is destruction of the renal cortex and sparing of the renalmedulla, is a relatively rare cause of acute renal failure. A definitive diagnosis of acute renal corticalnecrosis is based on renal biopsy, but on CT(computed tomography) the rather specific contrast-enhanced appearance of acute renal cortical necrosis has been described. As renal biopsy is not available, contrast-enhanced CT is auseful, noninvasive investigate modality for the early diagnosis of acute renal cortical necrosis. We report the characteristic CT findings of acute renal cortical necrosis in a patient with acute renal failure following anoperation for abdominal trauma.


Subject(s)
Humans , Acute Kidney Injury , Biopsy , Diagnosis , Early Diagnosis , Kidney Cortex Necrosis , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL